If a second measurement is needed, draw a fresh sample.Some experts recommend drawing and discarding a sample of at least 1 ml prior to drawing samples for coagulation testing.Use plain plastic syringes or plastic evacuated tubes with no anticoagulant, activators, or serum separators.The ACT test can be performed using venous or arterial samples, while the PT/INR test can be performed using capillary or venous samples. i-STAT 1 handheld Electronic Simulator List of the IP Address(es) for the network downloader(s) to be used for the software update process 1.2: Close all open programs on the computer.GST I-Stat Trop Ctnl Control - C/Chain 282.61 inc. + Add to cart Features Specifications You may also like Emergency Transtracheal Airway Catheter 6Fr 194.61 inc. GST SKU QMABB6F11.01 i-STAT is tested with Electronic Quality Checks using an Electronic Simulator to confirm analyzer performance. Do not “milk” finger or heel while collecting sample. I-Stat Electronic Simulator 1,895.39 inc.Allow alcohol to dry over puncture site before collecting sample.For all analytes including ionized calcium, use plain or balanced heparin capillary tubes. Skin puncture: Lithium heparin capillary tubes for testing all analytes but ionizedĬalcium. Do not leave tourniquet on for more than 2 minutes.Sodium heparin filled to capacity and mixed by gentle inversion at least 10 times. Venous: Collection tube with lithium or If not tested immediately, remix and discard 2 drops of blood before filling cartridge.Avoid drawing air into syringes for blood gas and ionized calcium tests.Test for other analytes within 10 minutes. Mix heparinized syringes by rolling between palms for at least 5 seconds in 2 directions, then invert the syringe repeatedly for at least 5 seconds. For ionized calcium, use balanced heparin syringes. iSTAT 1 iSTAT electronic simulator iSTAT printer +spare rolls of paper. Arterial: Plain syringe, heparinized syringe labeled for analytes to be tested and filled to capacity, or syringe with minimum volume of heparin to prevent clotting (10 U/mL of blood). Abbott iSTAT 1 300W Handheld Clinical Hematology Analyzer Includes: One Complete. If the analyzer passes the simulator check,Ĭontinue to use. Push cartridge straight through door until it Press on snap closure, and notĬartridge is underfilled or bubbles trapped Simulator testing occurred for the i-STAT System as a 20 second step before commencing patient measurements.10 The comparator. Check software version.Ĭalibrant released too soon. The analyzer could not identify the type ofĬartridge inserted. The software checks for an unrealistic date.Ĭheck Status Page. Software will expire 15 days after SFT is Hours, or as needed for regulatory compli.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |